  test procedure for the nc p1521b evalu a tion board 5/31/2007 equipment needed ? power supply ? digita l volt meter ? digita l am p meter test 1. jum p er enable shoul d be open. 2. jum p er select should be closed to 1.2v. 3. set the pow er supply to 3.6v and the current limit of at least 800m a . 4. connect the power supply connector to c onnectors vin+ and vin-. the dc current m easure m ent on vin line should be around 0.3a. 5. close enable connector. the dc current m easurem ent on vin line should be around 40a. 6. measure the output voltage between vout + and vout- con n ectors. you should see around 1.2v voltage operation. 7. re m ove the enable jumper. the dc current m easurem ent on vin line should be back around 0.3a.